Agilent GC/MSD Maintenance Schedule

Task

Every Week

Every 1~3
months

Every 6
months

Every
year

As
neede

°ßÀû
½Åû

樨毢

Change the carrier gas trap and purifier

 

 

O

 

 

 

 

ReNEWable Gas Purifier System- New S

G3440-60004

 

 

 

 

 

Trap, O2/H2O, 1/8"

OT3-2

 

 

 

 

 

Change the split vent trap

 

O

 

 

 

 

 

Split vent trap kit

G1544-60610

 

 

 

 

 

Change syringes or syringe needles

 

O

 

 

 

 

 

Syringe, 10ul straight, FN, 26s/42/HP(Autosampler Syringe)

9301-0714

 

 

 

 

 

Syringe, 10.0 uL, FN, bevel tip(Manual Syringe)

5190-1483

 

 

 

 

 

Change injection port liners

O

 

 

 

 

 

Liner,split,straight,glasswool,non-deact

19251-60540

 

 

 

 

 

Liner,splitls,sngl-taper,no glswl,deact

5181-3316

 

 

 

 

 

Liner,splitless,single-taper, glswl

5062-3587

 

 

 

 

 

Liner,split,low prs drop,glswl

5183-4647

 

 

 

 

 

Change Liner O-rings

 

O

 

 

 

 

Liner O-Ring, Non-Stick

5188-5365

 

 

 

 

 

Change Inlet septum

O

 

 

 

 

 

 

Non-Stick BTO Inlet Septa 11mm

5183-4757

 

 

 

 

 

Non-Stick Adv Green Inlt Septa 11mm

5183-4759

 

 

 

 

 

Non-Stick Long Life Inlt Septa 11mm

5183-4761

 

 

 

 

 

Change Inlet gold or stainless steel seal

 

O

 

 

 

 

Gold Plated Inlet Seal with Washer

5188-5367

 

 

 

 

 

Replace column

 

 

 

 

 

O

Universal column nut

5181-8830

 

 

 

 

 

MS interface column nut

05988-20066

 

 

 

 

 

Ferrules

 

 

 

 

 

O

 

Ferrule Graphite, column id 0.1, 0.2, 0.25, 0.32um

5080-8853

 

 

 

 

 

Ferrul Vespel/Graphite, column id 0.2, 0.25um

5062-3508

 

 

 

 

 

Ferrul Vespel/Graphite, column id 0.32um

5062-3506

 

 

 

 

 

Tune the MSD

 

 

 

 

 

 

 

Filament assembly(EI)

G3170-60050

 

 

 

 

 

Filament assembly(CI)

G1099-80053

 

 

 

 

 

Electron multipliers and replacement horn

05971-80103

 

 

 

 

 

Triple axis detector assembly_5975 series

G3170-80105

 

 

 

 

 

Triple axis detector electron multipliers_5975 series

G3170-80103

 

 

 

 

 

Check the foreline pump oil level

O

 

 

 

 

 

 

Replace the foreline pump oil

 

 

O

 

 

 

 

Foreline pump oil, Inland 45, 1L

6040-0834

 

 

 

 

 

Check the diffusion pump fluid

O

 

 

 

 

 

 

Replace the diffusion pump fluid

 

 

 

 

 

O

 

Diffusion pump fluid, 18.5mL

6040-0809

 

 

 

 

 

Check the calibration vial

 

 

O

 

 

 

 

EI Tune/PFTBA sample, certified

8500-0656

 

 

 

 

 

CI Tune/PFTBA MS sample Kit

05971-60571

 

 

 

 

 

Clean the ion source

 

 

 

 

O

 

Ion source cleaning kit

5181-8863

 

 

 

 

 